Understanding the Front End Documentation

The front end documentation is not contained within the CSI (Construction Specification Institute, Inc) MASTERFORMAT divisions (Division 22 – Plumbing, Division 23- HVAC, Division 26 – Electrical). We consider front-end documentation to be all the sections and information setout before division 1 of the specifications, including the RFP (request for Proposal), Instructions to Bidders, Supplemental Instructions to Bidders, or an Invitation to Bid.

This is the first place to begin an estimate. We will cover some of the information found in these sections, the RFP and Division 1 (General Requirements).

Invitation to Bid

The invitation to bid will provide you with most of the information you will need to make a decision on whether to bid the project and the timelines of the proposal.

Invitation to bid
Invitation to bid

Bid Date and Time

Make sure to post the date and time of the bid, along with the RFI deadline and any job walks on your Bid Log and Bid Schedule.

As can be seen in the above example Harris County is accepting bids until 1:00 pm, Tuesday, August 27, 2019 at the Harris County Board of Commissioners Office for a certain project. This is a public project and the bid date and time are usually strictly enforced. If you are a minute late, your bid will be rejected.

Pre-Bid Meeting or Job Walk

Is there a job walk scheduled for this project? Is the walk mandatory? Is this a renovation project?

If the job walk isn’t mandatory, you could show the owner or general contractor that you’re interested in the project by attending the job walk or any pre-bid meetings. Make sure to review the drawings and specifications before the pre-bid meeting.

If this is a renovation project, then the pre-bid job walk would be a great time to determine the existing conditions under which you will be required to work during construction.

Plans and Specifications

Plans and specifications are often purchased through a depository or printing company that holds the documents for a public or private entity. In the below example you would need to pay $200 for a copy of the documents which is mandatory to be considered for the submission of a bid. With concern for the environment and the cost of printing documents, many entities have moved to delivering their plans and specifications electronically.

Bidding Documents
Bidding Documents

Pre-Qualification of Bidders

There are often requirements that a company wishing to bid a project must provide evidence of previous experience with a project of a similar scope. This particular project has a dollar threshold for differing pre-qualifications, one for under and another for being over $2,000,000.

Bid Bonds

A Bid Bond will need to be provided by your surety in order to bid this project. This project requires a bid bond in the amount of 5% of your bid; often this is 10%. The bid bond ensures that you execute the contract at your bid price if you are the low bidder. In some event where you find yourself disqualified or you refuse to execute the contract, you can be liable for an amount equal to the difference between the amount of your bid and the next lowest bidder that the owner executes the contract with for the same scope of work, usually the next responsible lowest bidder.

Bid Bond
Bid Bond

A bid bond is provided as a courtesy from your bonding company if you do enough work with them and have a good payment history.

Your liability should not exceed your bond amount. Failure to sign the contract and to furnish all items required by the bidding documents is ground for forfeiture of your bid bond.

A bid bond is provided as a courtesy from your bonding company if you do enough work with them and have a good payment history.

Performance and Payment Bonds

Federal, state and municipal projects usually require that you provide a Performance and Payment bond. The cost of this bond will need to be added to your proposal as your surety will charge you for this insurance. The performance and payment bond is to ensure the public entity that you will pay the  material and labor expended for this project, along with payment to any subcontractors or vendors that furnished equipment or labor on your behalf. The cost of this bond will depend on your bonding capacity and history of paying such bonds.

Reservation of Rights

Reservations of rights allows the public entity the ability or right to reject any and all bids that it sees unfit according to the standards or criteria established by the owner.

Reservation of Rights
Reservation of Rights

Bid Forms

Bid forms are a set of forms to be completed and sent in with your bid when bidding public projects. Privately funded projects don’t always use bid form, so you will prepare a proposal letter that contains all of your scope of work, exclusions, clarifications and assumptions.

Bid forms will include your price breakdown, alternate pricing, unit pricing, recognition of any addendums, performance and payment bond rate, along with your bid bond if required. Information about your company, including an authorized signature will be required.

Unit Price

Does the project require you to submit unit pricing along with your bid? This can take some time to put together if you don’t already have some numbers generated. How much does your company charge if the owner decides to add 20 feet of 10” round ductwork and a ceiling diffuser, or to add a 12” x 12” fire damper? Unit pricing allows the owner to add or deduct items from the scope of work based on the unit prices you provide for each item. See the MEP Academy HVAC Piping Unit Pricing spreadsheet, that makes the creation of unit prices easy.

Unit Price
Unit Price

Allowance

Sometimes the owner will request that you include an allowance in your bid for a potential scope item that hasn’t been well defined yet, but for which the owner wants included in the cost proposal.

Bid Allowance
Bid Allowance

Alternate

An alternate is for a specific scope of work or material not included in the base bid. The bid price for the Alternate is not included in the Base Bid amount. Alternates may be Additive or Deductive. The bid price for the Alternate should only represent the amount for the Alternate over and above the Base Bid work. See an example Additive Alternate below.

Additive Alternate 3
Additive Alternate 3

Addendum

Have any addendums been issued? All Addendums issued will become part of the contract, including any issued before the bid date. Addendums could be in the form of drawings, specifications or clarifications. It’s important to make sure you have the latest set of drawings and that all addendums are accounted for.

Also, it’s important that you assess the addendum for any impact it might have to cost, schedule or your vendors and subcontractors. Make sure to indicate that you have included the addendum in your proposal, and if it’s a public bid, then there should be a spot on the bid form for indicating the addendum number and date as shown below.

Addendum
Addendum

Liquidated Damages

You won’t put any cost for this in your estimate as the intent is to complete the project as defined in the specifications to avoid incurring a liquidated damages penalty. This might be found in the section entitled progress schedule, where it states that if the project goes past its scheduled completion date, there will be damages assessed. This is a penalty for delaying the completion  of the project, and is usually stated in so many dollars per day for every day that you pass the scheduled completion date, such as $500 per Day.

Here is what the government inserts into their contracts related to liquidated damages. They allow the governments contracting officer the right to determine what the penalty will be on any government contract that they are overseeing.

(a)If the Contractor fails to complete the work within the time specified in the contract, the Contractor shall pay liquidated damages to the Government in the amount of ____________ [Contracting Officer insert amount] for each calendar day of delay until the work is completed or accepted.

(b)If the Government terminates the Contractor’s right to proceed, liquidated damages will continue to accrue until the work is completed. These liquidated damages are in addition to excess costs of repurchase under the Termination clause.

Introduction to Sheet Metal Estimating (Free Course)

Introduction to Sheet Metal Estimating

Welcome to the course that will teach you how to Estimate HVAC Sheet Metal for the commercial industry. If you are mostly working in the HVAC residential industry, then this course will allow you to see what is involved to enter the commercial industry, while also giving you good estimating practices. In this course we will cover the steps needed to complete an HVAC Sheet Metal Estimate from material takeoff to field laboring.

The first section will cover the requirements needed to read engineered drawings, and what to look for in the plans and specifications that are applicable to the HVAC estimate. This includes understanding how to read the symbols used on drawings, and how to read the various CAD generated lines and the basic drawing layout. The building should be built just as its shown on the drawings and as indicated according to the specifications.

At the end of each section, there will be a short quiz to help you remember the material that was covered in that section.

The drawings that are used to bid the project will become part of the contract if your company is the winning bidder. So it’s important that you read through the drawings and specifications completely to ensure that you have all the cost covered to make for an accurate bid, one that will provide a profit for your company.

There are several different sets of drawings created for the construction or renovation of a building. The one that we will be focusing on are the Mechanical set, specifically the HVAC portion of the mechanical drawings.

Who are the Players in a Construction Project

There are various players in any construction project. Depending on the delivery method, which there are three that are mostly used in construction: Plan and Spec, Design/Assist, and Design/Build. The parties to a construction contract are as follows.

Project Owner (Private or Public)

The owner can be a public or private entity and is the one behind the reason or purpose for building or renovating a construction project. In the private sector this could be an individual or more likely a corporation. For the public sector this is usually your local, state or federal government which has more stringent and regulated bidding requirements then the private sector.

Ownership
Ownership

The owner provides the money or can secure the funds for the project. They will hire the design team under the Plan and Spec delivery method, which includes the Architect and the associate trade engineers such as the Mechanical, Electrical, Plumbing and Structural engineers.

Plans and Specs Contractual Hierarchy
Plans and Specs Contractual Hierarchy

Design Team

Under a plans and specification delivery method, the private sector owner will hire an architect to carry out the design according to the owners directive and needs. The architect will hire all the other designers needed to provide a complete set of engineered drawings. These drawings will then be sent out with an (RFP) request for proposals from a list of approved general contractors.

Building Design Team
Building Design Team

General Contractors (Prime Contractors)

The General Contractor will manage the construction project, using some or none of their own labor, and for which the owner contracts with for the construction of the project. The General Contractor will invite 1st tier subcontractors to provide bids on their respective trades, this would include the MEP (Mechanical, Electrical, Plumbing) trades, in addition to all the other trades.

1st Tier Subs
1st Tier Subs

1st Tier Subcontractors

This is the level where the mechanical, electrical, plumbing and all other trade contractors will receive their subcontract agreement from the general contractor. There are instances when the contract will be directly with the owner, but in the most cases a General Contractor will be used in a plan and spec delivery method. This is the first tier of subcontractors to the general contractor, the next tier will be the subs of the subs.

2nd Tier Subs and Vendors
2nd Tier Subs and Vendors

2nd Tier Subcontractors

These are the contractors that get hired by the first tier subcontractors, which makes them the second tier subs to the general contractor as shown in the diagram. If you are the mechanical contractor, then you might hire an Water and Air balance company or an insulator to insulate the air conditioning ducts and piping.

Suppliers

You will also have agreements in the way of purchase orders with suppliers for the purchase of the equipment and materials needed to carry out the mechanical portion of the scope of work. During the bidding process they will provide quotations based on the plans and specifications as designed by the mechanical engineer.

Bidding Cycle
Bidding Cycle

Estimating by Construction Activity/Construction Work Element

Before estimators can create a detailed estimate, projects must be broken down into smaller parts, so each part can be individually estimated. A subset of material, equipment, and labor estimates is created for each construction work element.

For example to install a 50 foot section of duct in a high bay area would require the following:

  1. (Material) The material estimate identifies required quantities of duct, fittings, air distribution, and any sheet metal accessories.
  2. (Rentals) The sheet metal estimate identifies that a scissor lift is required to install the hangers and ductwork.
  3. (Labor) The sheet metal takeoff provides the quantity of hours and the number of man-days required to perform work.
  4. (Fabrication) The takeoff identifies the pounds of sheet metal that has to be fabricated or purchased.

Items required for Estimators

The following items should be provided to you by the salesperson or the general contractor, or whoever is responsible for bringing in the documents.

  1. Drawings and specifications (Plans and Specs)
  2. RFP (Request for Proposal) and a narrative description of the project’s scope
  3. Bid Forms if applicable
  4. Project schedule
  5. Bid conference or job walk date
  6. Bid date and time
  7. Method of delivery for bid

What makes a Good Estimator?

The estimator must;

  1. Visualize the separate operations of the job as the work would progress through the various stages of construction
  2. Read, conceptualize, and obtain measurements from drawings
  3. Have knowledge of mathematics, previous construction experience, and a working knowledge of all branches of construction
  4. Have good judgement when determining what effects numerous factors and conditions will have on the construction of the project and what allowances should be made for each of them including labor adjustments.
  5. Do accurate work and present it in a complete and organized format for an estimate review and handoff to operations if the project is successfully won.

SMACNA Company Spotlight – Black & McDonald

Black & McDonald, a Canadian based multi-trade contractor with offices across Canada and the United States. Watch this video to learn a little about how an experienced HVAC contractor conducts business. You can see their fabrication shop is setup to be efficiently run.

SMACNA Spotlights Black and McDonald Company

Prequalifying The Bid

It’s not feasible to bid everything that is available, as you will spend a lot of time and money chasing after work that you have very little chance of winning. This is why it’s important that you have some method to determine whether a certain project is worth the time and money to pursue.

Prequalifying is a set of questions that you ask of the opportunity to determine if it rates high enough to warrant pursuing it further. Here are some questions you might ask about the opportunity before you make a decision to pursue it.

Bid Risk Assessment

Having some form of rating system will help you make a decision whether or not to bid a project based on some form of evaluation of the opportunity for success, such as the MEP Academy “Bid Risk Assessment” form which is part of the MEP Academy Estimating Spreadsheet.

Bid Risk Delivery Method
Bid Risk Delivery Method

Project Delivery Method

There are several delivery methods from Design/Build to Plan & Spec. Each delivery method has more or less risk associated with it. The delivery method runs horizontally across the top header, and the entity accepting the bids runs vertically on the chart.

Design/Build means that you are responsible for the design and construction of the project. This means you either hire the mechanical engineer to be part of your team or you have in-house engineers that will design the project. This would make you the design-build contractor.

Design/Assist means that there is a 3rd party engineer that you will assist in the development of the materials and methods of construction and any value engineering ideas you have to make the project meet the owners budget and performance objectives.

The Plans and Specifications mean that there is a 3rd party engineer that designs the project and then mechanical contractor compete to build the project according to those plans and specs. You the contractor have no responsibility of the design, and should receive a change-order for any changes or corrections to the drawings that add cost to the project execution.

Design/Build projects allow you better control of the design, materials and methods of construction and so they usually allow for better margins or profits. This would be considered less risky and earn a lower score, meaning less risk on the assessment form and a better opportunity.

Plan and spec projects are usually more competitive and the opportunity for making profits that are comparable with the design-build delivery method are less, so this would rate a higher risk value.

Projects Bids to

The vertical column assesses who your competition is and who you are bidding to. Being the “Only Bidder” as shown on the top row would of course be the best position to be in as a bidder, so this would rate a low value or low risk factor.

The last row shows having “Multiple GC’s”, that is there would be more than one general contractor that you would have to submit your price to in order to have the greatest chance of winning the project. With more general contractors, there will be more mechanical contractors bidding, as each general will invite their typical three or more regular mechanicals to bid. This is the worst case scenario as the competition will be high and the margins driven lower in order to compete and win the project, so this gets the worst score in this category.

Looking at the above “Bid Risk Assessment Form” you see that bidding on a project that is Plan and Spec’s with Multiple GC’s will get you a high score of “10” points, which isn’t good. The risk assessment score is like a golf score, the lower the score the better, or in this case the less the risk the lower the score. Looking at the same form shown below, but this time we are bidding a Design-Build project and we are the only bidder, this gives you a score of “1”, which is good. Obviously this opportunity has less risk in the way of being the successful, which is what this form was created to determine.

Bid Risk Assessment Form in the MEP Academy Estimating Spreadsheet
  1. How many other Sheet Metal bidders are there? You don’t want to be bidding against a large pool of bidders, unless you think that you have a lower overhead cost then the competitors.
  2. How many General Contractors are bidding the project? If you are bidding to a general contractor, then you will need to know if they are bidding against a pool of other general contractors. The more general contractor there are bidding the project, the less chance you have of winning the project.

If there are four generals bidding and each one of them invites four mechanical contractors to bid the project, then it’s possible that you are one bidder out of sixteen possible sheet metal contractors. What’s the chance that you will win against fifteen other bidders. If you do win, what’s the chance you’ll make money having been the low bidder out of sixteen bidders?

  • Does the project have funding approved?
  • Is the schedule reasonable and do you have the field labor to perform the work when required? 
  • Is the decision based on low price?
  • Are there any non-union bidders? If you are a union contractor trying to compete against non-union contractors you could be at a disadvantage on labor cost, unless the union grants some form of concession.
  • Do you have a relationship or experience working with the general contractor or owner?

Estimates that Lose Money

If you are an estimator long enough, you will have estimates that don’t make a profit as anticipated at time of the initial bid. This can be caused by many reasons. Some of the most common include;

Errors. Some of the causes of errors include not reading all the specifications for the requirements, or reviewing all the details and notes on the drawings. Errors can occur because of being rushed to get a project bid without the time to do your due diligence with all the bid documents.

Labor Productivity in the field may not have produced according to the assumption made at bid time. This could be due to unforeseen project conditions that increased the difficulty for the installers to hit the labor productivity factors assumed at bid time in the estimate.

Was the estimate short on material or equipment cost?

Was there adequate rental equipment cost in the bid, including the proper duration or the time required for its use?

Was the project schedule extended, requiring additional cost for extended general conditions?

Whatever the reason, you should have a closeout meeting with the project management team to determine a better approach on the next project that poses similar risk possibilities.

Sometimes it’s just not possible to predict how a certain general contractor or owner will manage the construction project, and how that will impact your labor. By having a strong project management team on the project to ensure that any legitimate change order is procured can help minimize or mitigate the risk of poor management of the construction by the general contractor or owner.

Bidding on Federal Construction Projects

All GSA (General Services Administration) design and construction contracting opportunities are advertised on the Federal Business Opportunities (“FedBizOpps“). To receive drawings and specifications for projects, contractors must be registered in the System for Award Management (SAM) system and in FedBizOpps, as drawings and specifications are usually issued electronically there. Announcements will contain instructions on obtaining classified drawings and specifications which are not distributed through FedBizOpps. The following areas are included in construction.

Beginning an Estimate

Deciding on whether to bid a project or not is sometimes beyond the estimators role. Often, a salesperson, contract executive, construction manager, Vice President, owner or some other individual will make the decision of whether or not to proceed on a bid. Some of the factors that go into the decision could be;

  • What is the availability of our staff to run this project?
  • What is the projected availability of field personnel to install the project according to the project schedule?
  • Who is the competition?
  • Who are you bidding to?
  • Do they pay on time?
  • Do they manage a project in a proficient way?
  • Are there multiple general contractors?

Once the decision has been made to proceed with a project it is best to begin by following the procedures outlined in this course, you will ensure that each and every estimate that you assemble will be done in the most efficient and fail safe method, thus avoiding costly mistakes.

Bid Schedule

After the decision is made to pursue a project, then there should be somewhere that the name, date and time is displayed for the estimating team and for vendors that visit your office.

Below is the minimum information that you should have when tracking bids and their due dates.

Due Date & Time: When is the bid due and at what time? Depending on whether the bid is public or private can make a big difference on the actual submission time. Most public entities won’t accept bids that are submitted a minute late, while private companies have more leeway.

Project Number: This should match the project number entered on the bid log above in order to track all the records related to the bid.

Project Name: Usually this is the name on the drawings and specifications and what everyone will referred to, especially working with your vendors and subcontractors.

Estimating Bid Schedule
Estimating Bid Schedule

Bids To: List who the bid will be sent to. If it’s a public bid then there could be specific instructions in the bid documents on how to address the envelope and how many copies are required.

Lead Estimator: If you have multiple estimators, then list the estimator assigned to lead the estimate.

Job Walk: List the date and time of any job walks. There are some job walks that are mandatory in order to submit a bid. At these job walks or project conferences there will be a sign-in sheet to confirm to everyone who was present at the mandatory meeting.

RFI Deadline: You will need to study the drawings and read the specifications to derive at any questions that you might want to submit as an RFI (Request for Information). RFI’s help clarify items on the drawings, specifications or from the job walk site visit.

Bid Log

Next you will want to record the project into an estimate log and assign it a proposal number. This will allow you to provide a year-end report on various parameters related to success ratios, project types and delivery methods.

Bid Log
Bid Log

Estimating Bid Log

After you finish the estimate, you should record the pertinent information into a bid log. If you are using one of the many software programs for tracking bids, then this would be automated with that program.

The bid log should be something similar to the above. The bid log is used to keep track of the order in which projects arrive into the estimating department and for reference when looking back to check an old estimate.

Proposal #: Put the estimate number on all documents related to that bid, especially the estimate spreadsheet and proposal. The numbering system shown above includes the last two digits of the year, followed by the number of the project bid in that year. As shown in the example above (20-1001), this bid was the first bid in the year 2020. You should create a estimate tracking system to keep track of the estimates that you work on. This will make it easier for you to reference at a later date.

Date Received: Enter the date you received the documentation and the name of the project.

Bid Amount and Margin After the project bids you can enter the bid amount, margin and latter if you won or lost the project. You can include any information that you deem important for your company to track.

Delivery Method: P & S is the abbreviation for Plans & Specifications and is your typical Design-Bid-Build process of construction. D/B would indicate Design-Build, a much different process than plan and spec. This course will cover the P&S (Design-Bid-Build) process, but many of the procedures are applicable to both. See our other course on Design/Build.

Building Type: Tracking the building type is for historical reasons. Often your looking for a project to compare an estimate that is of a similar building type.

Salesperson: Indicate the individual that brought the project into the estimating department or the individual that is responsible for presenting the project proposal to the company receiving the bids.

Wins and Losses: The bid log will help to total the dollar amount of  the projects won and loss for the year, and the success ratio.

Bid Notification

There are a lot of software programs available that automate vendor and subcontractor notification.

List the name of the project, the engineer and the bid date. The reason the engineer is important is because some vendors assign their salespeople according to who the engineering firm is. The vendor bid notification should be filled out early in the process, so that everyone that needs to provide pricing has a reasonable amount of time to do so.

Poor estimating practice is to notify the vendor and subcontractors late in the bidding process, forcing them to be hurried in preparing their bid. The less time you give your vendors and subcontractors to prepare the more likely that their price will be uncompetitive.

Introduction to Sheet Metal Estimating (Free Course)

Estimate Summary Sheet

Chapter #8 – Estimating Summary Sheet

We will use the MEP Academy Estimating Spreadsheet for all our examples. Hopefully the estimating spreadsheet your company uses is as versatile, if not, maybe you could suggest they purchase the MEP Academy Estimating Spreadsheet. This section of the course will cover the front page of the estimating spreadsheet which summarizes the totals from all the individual pages, plus provides some important metrics.

After completing all other task, it’s time to put any values you already have into your spreadsheet to get an idea of the magnitude of the project. Be sure to identify clearly what contains a plug number. Most of your plug numbers will be for HVAC equipment pricing and subcontractor cost. This should be done at a minimum of two days before the bid is due, never on bid day, which can be very hectic.

The plugged numbers will also help you in determining the bid bond amount if required. Remember plug numbers are based on historical cost data that you have saved for just this purpose.

Be sure to have your bid bond ready to go if required.

If the price has to be sealed in an envelope and delivered within a certain time, be sure to have the envelope addressed as required and ready with all bid documents filled out ahead of time, except for the price. It may even require stationing someone with a cell phone at the bid drop off location on the day, and right before the closure time for responsible bidders. 

Project Set-Up

The MEP Academy Estimating Spreadsheet has several sections, but at the top of the spreadsheet is where you will put the project information.

Begin by typing in the name and address (#1) of the project, delivery method (Design-Build, Design-Assist, Plan & Spec)(#2) and the bid date (#3). Add the proposal number (#4) to keep track of all your proposals and the Tax Rate (#5) for the city or location of the project.

MEP Academy Estimating Spreadsheet
MEP Academy Estimating Spreadsheet

Sheet Metal Summary

The Sheet Metal Summary (#6) brings forward all the totals from the Sheet Metal Material and Labor Summary sheet along with the Sheet Metal Specialties sheet and equipment labor related to the sheet metal trade.

Also shown is the percentage (#7) of the total cost attributed to the Sheet Metal trade. Everything that is shown in a bright blue font is editable, the rest of the cells are protected. You will need to enter the labor rates for the detailer and for supervision (#8). The total material and labor cost for the sheet metal trade is shown in item (#9).

Piping & Plumbing Summary Sheet

For those companies that provide HVAC Piping and Plumbing in their business, there are separate sheets within the MEP Academy Estimating Spreadsheet that can be used. These summaries are similar to the sheet metal summary section as they bring forward the total material and labor from the trade tabs of the spreadsheet.

MEP Academy Estimating Spreadsheet Piping & Plumbing
MEP Academy Estimating Spreadsheet Piping & Plumbing

Air & Water Balance/Start & Test

If the specifications allow and your company has the capacity to perform their own Air & Water Balance (#10) there would be a value shown here on the front of the spreadsheet. Most plan and specification project usually require a 3rd party company to do the air & water balance to avoid any appearance of a conflict of interest.

MEP Academy Estimating Spreadsheet Balancing
MEP Academy Estimating Spreadsheet Balancing

Engineering

The engineering summary is for those projects where you are responsible for the engineering and design.  In a plan and spec delivery format this wouldn’t be required, as the drawings and specification have already been completed by a 3rd party mechanical engineer.

HVAC & Plumbing Equipment & Fixtures

This section provide the total cost for the HVAC & Plumbing equipment  in addition to the plumbing fixtures. Remember that all these values are summaries from other pages in the estimating spreadsheet. Everything is just summarized on the Final Estimate Summary Page.

MEP Academy Estimating Spreadsheet HVAC and Plumbing Equipment
MEP Academy Estimating Spreadsheet HVAC and Plumbing Equipment

Subcontractors

Once again this is just a summary of your subcontractors page for all the HVAC and Plumbing Subcontractors for this project.

MEP Academy Estimating Spreadsheet Subs
MEP Academy Estimating Spreadsheet Subs

General Conditions

Most of these cost come from the General Conditions tab of the MEP Academy Estimating Spreadsheet. Item #12 shows what percentage general conditions are to the total cost, while item #13 shows what percentage the particular line item general condition is to the total General Conditions cost (#14). Also there are additional line items for anything the user would like to add. This gives a quick overview of the general conditions cost on the front sheet.

MEP Academy Estimating Spreadsheet GC
MEP Academy Estimating Spreadsheet GC

Contingency, Margin and Sales Price

After reviewing all of the above, now it’s time to make the decision on how much contingency to carry and how much profit and overhead to add to your bid.

Contingency

You can think of contingency as cost that could occur, but is not certain to occur. Contingency is to cover unforeseen cost that could reveal itself during construction. Contingency covers the risk associated with the unknown and is greater in underdeveloped drawings. When bidding on plans and specification type projects the contingency factor should be at the lower end of the spectrum, because the 3rd party engineer is taking the liability of showing and describing what is needed, and if anything is missing or incorrect then a justified change-order should be allowed to set things right.

Theoretically you shouldn’t need a contingency factor on a plan and spec project, but if you’re not fully comfortable with your own accuracy of a complete bid, then adding a small percentage could give you a better night’s sleep and provide for a small margin of error on your part.

Spreadsheet Contingency
Spreadsheet Contingency

With the MEP Academy Estimating Spreadsheet it’s easy to add a contingency factor (#17), just choose what the percentage you would like to add and the spreadsheet will automatically calculate the amount based on the subtotal cost (#16).

Spreadsheet Margin
Spreadsheet Margin

In the example above you can see that a 2% contingency (#17) added to the subtotal cost (#16) equals $10,617. From this new total you will choose the margin percentage (#18) that you want. The margin is where you recover your overhead and hopefully make a profit.

Alongside the margin is the markup which shows a much higher percentage (#20) as they are based on different formulas. What’s the difference between margin (#18) and markup (#20)? The margin informs you of what percentage the margin is to the total sales price, while the markup percentage is what you multiply the cost by.

Margin = $135,363 / $676,813 = 20% ($541,450 / (1 – Margin Percentage) = $541,450/0.80

Markup = $541,450 x 25% = $135,363

Estimating Spreadsheet Markup
Estimating Spreadsheet Markup

Project Metrics

The first metric is the cost per square foot (#21) shown above. This is a useful number for price checking or budgeting of future similar projects.

Your estimating spreadsheet should be capable of providing you with the various metrics that allow you to price check engineering and cost parameters.

If you’re using the MEP Academy Estimating Spreadsheet then indicate the building type and the square footage (#22) of the area being conditioned or developed. Square footage will be used to calculate the different parameters for analysis, such as Cost per Square Foot (#21), while the quantity of stories will help you compare this project to similar projects in your historical database or future projects.

Estimating and Engineering Project Metrics
Estimating and Engineering Project Metrics

Total Supply Air CFM (#23)

By entering the total supply air CFM this will give you two important engineering metrics that can help you when budgeting. For example if you had another similar building that was in its conceptual phase, where there is no design yet, this would allow you to come up with the total CFM and tonnage based on only the square footage of the proposed building.

Cooling Metrics (#24)

This is similar to CFM, except that this will also give you the cost per ton for the project, which again is very useful when doing quick budgets without the design being completed or as a quick check figure.

Heating (#25)

Another engineering metric that maybe useful in the budgeting of the heating system for a similar building that hasn’t been design yet, but for which the owner or General Contractor would like a budget based on the conceptual drawings and the total square feet of a proposed building.

Plumbing Metrics

The MEP Academy Estimating Spreadsheet also has plumbing metrics that measures material, or the material & labor cost per fixture.

Plumbing Metrics
Plumbing Metrics
MEP Academy Estimating Spreadsheet

Understanding the MEP Estimating Spreadsheet (Free Course)

Purchase the MEP Academy Estimating Spreadsheet here >>> MEP Academy Spreadsheet

HVAC Quotations – MEP Estimating Spreadsheet

Chapter #2 – HVAC Quotations (MEP Estimating Spreadsheet)

Receiving, reviewing and posting vendor and subcontractor quotes to your estimating spreadsheet is time consuming for larger projects. Reviewing then as soon as you receive them will help reduce the stress on bid day of having to request changes from your vendors for any errors on their quotes.

Its unfortunate but you’ll most likely receive some of the quotations on bid day which can be a hectic day if the project is large or complicated.

Request that vendors provide you with pricing at least one or two days before the bid day, to allow you to review and comment on their quote. Remember that it’s very important you spend time reading the vendors and subcontractors quotes for possible errors and exclusions. Also, review the quote to ensure the proper quantities and compliance with the specifications.

If you know that you will have to analyze vendors that package several equipment items together, you can use the “Equipment Pricing Analysis” form below the first page of the equipment sheets on your estimating spreadsheet under the equipment tab.

HVAC Equipment Pricing Analysis

It’s unfortunate but some vendors will refuse to break up a bid package. The equipment vendor maybe representing more than one HVAC manufacture. The vendor then decides that they will package all the various manufactures HVAC equipment that they represent into one large bid, and refuse to give you breakout prices for each category of equipment.

The packaged bid might include the Cooling Towers, Pumps, Chillers and VFD’s. The analysis is based on all the vendors bidding on approved equal equipment.

For example let’s say that below are the six bids that you received, each bidding on a different lot of equipment.

Project Vendor Quotes
Project Vendor Quotes

You will need some way to compare the six bids to see what is the most competitive combination of prices. It’s easiest to do that using a simple Spreadsheet or chart. This comparison chart is located in the MEP Academy Spreadsheet.

Using the vendor quotes from above, you can put them into the chart below in order to compare them. 

Looking at the below comparison chart, how would you know that the packaged bid from Vendor #1 (red circle #2) which includes all the listed equipment, is the best price compared to everything else you have received? Looking at the scope of work for each vendor won’t easily reveal the most competitive combination of prices without some way of comparing them.

Equipment Price Comparison
Equipment Price Comparison – MEP Academy Estimating Spreadsheet

Fill in the separate pieces of equipment that are being packaged under the column heading ‘Item Description” shown at the (red circle #1 above). Put the vendors bid price for their lot of equipment under one of the Vendor columns for Vendor #2 through Vendor #6.

Under each vendor type the letters “Included” in the space next to the equipment that is included in their bid package price, or list the separate price for each item that the vendor has broken out, such as vendor #2 has bid $115,000 for the cooling towers and $140,000 for the chillers, but has no bid for the pumps and VFD’s which is shown highlighted in yellow.

After you record the prices of all the vendors, you will be able to see the gaps (yellow highlighted boxes) in their pricing for the equipment that they’re not bidding.

Equipment Price Comparison Chart
Equipment Price Comparison Chart

The gaps need to be filled in using another vendor’s price for only the items that are missing. This allows for a comparison between two or more vendors that are packaging their quote, but for which the various packaged prices are not completely the same in scope of equipment.

The example above shows vendor #1 submitting a bid of $345,000 for the Cooling towers, Pumps, Chillers and VFD’s. This is the packaged bid that we need to determine whether it’s a good or bad price.

The best way to analyze the quotes is to plug values from other vendors or use deductive reasoning based on historical data. The latter method involves substituting what you believe a piece of equipment is worth based on what you have paid for similar equipment in the past, and then either adding or deducting that from a packaged price to find the relative value of the remaining equipment.

After analysis between vendor #1 & #4 above, it is clear that vendor #4 is low bidder based on using vendor #3 to complete the total price. At this point you would include the price of Vendor #4 for the Chiller and Pumps and Vendor #3 for the Cooling Tower and VFD’s, as this combination is lower than the packaged bid of $345,000 form vendor #1.

If you just used the packaged bid of $345,000, than you would have been 13% higher than the combination price available with vendor #3 & 4.

Quotations by Telephone

If taking a quote by phone make sure that the vendor follows up with a written quotation. When taking a quote over the phone you need to ensure that they have seen all the drawings, specifications and any addendums.

You will need make sure that they have the correct quantities and confirm what they are excluding. It is in your best interest not to take phone quotes without having a written quotation, especially on expensive or complicated systems.

Per Plans and Specifications

Is the vendor bidding according to the plans and specifications? Often vendors will bid on items that they have not been approved for. Such as, if the specifications call for a certain make and model number for a piece of equipment, and the specifications clarify that no other equipment will be accepted, or that only those listed as approved equal will be considered.

Taxes

Make sure that the quotation doesn’t include taxes if you will be using a spreadsheet that adds taxes to your equipment.

Shipped Broken Down

If you notice that the equipment comes broken down in multiple pieces for shipping or for getting it into the existing openings, then make sure you have the additional labor covered for this.

Addendums

Does the vendor acknowledge any addendums? Were there any addendums issued on this project after the vendor received the original set of plans? Did you notify the vendors and subcontractors of any addendums that were issued?

When you receive an addendum it is important that you notify all your vendors and subcontractors so that they have the latest information, as it’s possible that the addendum will impact their pricing.

Faxes

The use of the FAX machine is diminishing as email as replaced much of their usage. But if your still using a FAX machine, be sure to check it for any quotation that may have been sent using this method. It’s always a good idea to get in early on bid day and check the fax for those quotes that arrived overnight.

Understanding the MEP Estimating Spreadsheet (Free Course)

Get a copy of the MEP Academy Spreadsheet here >>> MEP Academy Spreadsheet