Facebook
Instagram
Pinterest
Twitter
Youtube
Home
Sheet Metal
HVAC Piping
Electrical
Controls
Plumbing
Courses
How to Read HVAC Blueprints
Certified HVAC Piping Estimator
Sheet Metal Fabrication & Shop Labor Analysis
The MEP Estimating Process
HVAC Piping Labor Analysis
Understanding the Estimating Spreadsheet
Sheet Metal
Sheet Metal Field Installation 101
Sheet Metal Shop Fabrication 101
Sheet Metal Takeoff 101
How to Read Construction Drawings
Shop
Air Purifiers
Are Air Purifiers Safe to Use? Best and Worst Types Explained
How Long should you run an Air Purifier: AQI and Room Size
What Is CADR? Understanding Clean Air Delivery Rate for Purifiers
Air Purifier Placement Tips.
Air Purifier vs. Humidifier: Which Do You Need?
Portable Air Conditioner vs Air Purifier: Key Differences Explained
Search
Sign in
Welcome! Log into your account
your username
your password
Forgot your password? Get help
Privacy Policy
Password recovery
Recover your password
your email
A password will be e-mailed to you.
Sunday, June 8, 2025
Sign in / Join
Buy now!
Facebook
Instagram
Youtube
Home
Sheet Metal
Spiral vs Flexible Duct
HVAC Equipment Cost Database
Construction Job Walk Basics 101
Sheet Metal Takeoff – Test 3
HVAC Piping
HVAC Piping Labor Analysis
Direct Return vs Reverse Return Piping
Chilled Water Pumping Options
Refrigerant Piping Design Basics
Electrical
Automatic Transfer Switch
Daylighting for Health and Energy Savings
Electric Vehicle Charging Station
3-Way Switch Wiring Explained
Controls
Can AI Run a Building Better Than a Human?
Building Automation System (BAS) Overrides: Risks, Failures, and Best Practices
Refrigerant Monitor in Chiller Room
Supply Air Temperature Reset
Plumbing
Courses
How to Read HVAC Blueprints
Certified HVAC Piping Estimator
Sheet Metal Fabrication & Shop Labor Analysis
The MEP Estimating Process
HVAC Piping Labor Analysis
Understanding the Estimating Spreadsheet
Sheet Metal
Sheet Metal Field Installation 101
Sheet Metal Shop Fabrication 101
Sheet Metal Takeoff 101
How to Read Construction Drawings
Shop
Air Purifiers
Are Air Purifiers Safe to Use? Best and Worst Types Explained
How Long should you run an Air Purifier: AQI and Room Size
What Is CADR? Understanding Clean Air Delivery Rate for Purifiers
Air Purifier Placement Tips.
Air Purifier vs. Humidifier: Which Do You Need?
Portable Air Conditioner vs Air Purifier: Key Differences Explained
Search
LEARN MORE
LEARN MORE
LEARN MORE
Online Courses - Certified HVAC Piping Estimator
Learn to read drawings and HVAC Piping Estimating
LEARN MORE
Latest Articles
Plumbing
5 Practical Home Plumbing Upgrades to Help Conserve Water and Energy
MEP Academy Instructor
-
December 29, 2022
HVAC Engineering
Heat Recovery Ventilator
MEP Academy Instructor
-
December 27, 2022
Business
Digital Planner for Construction Estimators
MEP Academy Instructor
-
December 22, 2022
HVAC Engineering
How do Geothermal Heat Pumps work
MEP Academy Instructor
-
December 19, 2022
HVAC Engineering
How do Evaporative Coolers Work
MEP Academy Instructor
-
December 13, 2022
HVAC Engineering
How Gas Furnaces Work
MEP Academy Instructor
-
December 6, 2022
HVAC Systems
How do Air Conditioners Work
MEP Academy Instructor
-
November 30, 2022
HVAC Engineering
How do Chilled Beams Work
MEP Academy Instructor
-
November 21, 2022
HVAC Engineering
Why is my Air Conditioner not Cooling
MEP Academy Instructor
-
November 18, 2022
Estimating
Plumbing Estimating Spreadsheet
MEP Academy Instructor
-
November 8, 2022
1
...
12
13
14
...
23
Page 13 of 23
LEARN MORE
Subscribe to our Newsletter
*
indicates required
Email Address
*
Shop for Spreadsheets & More (Click Here)
How to Read Pump Curves
How to Read the Specifications
Estimating Spreadsheets
HVAC Spreadsheet (Link)
View all elements
Plumbing Spreadsheet
View all elements
HVAC & Plumbing Spreadsheet
View all elements
Residential Spreadsheet
View all elements
Drone Use in Construction
LEED Certification Explained
Chilled Water Pumping Options
Bypass Damper HVAC VVT System
Post Categories
HVAC Engineering
83
HVAC Systems
72
Sheet Metal
44
Estimating
39
Engineering
34
Business
29
IAQ Indoor Air Quality
25
Controls
23
HVAC Piping
20
Plumbing
18
Electrical
17
Sheet Metal Field
14
Construction Drawings
12
How Steam Traps Work
Learn how Steam Traps Work
Read more
Steam Heating System Basics
Steam Heating System Basics
Read more
Plan | Elevation | Section Views and Details
Chapter #3 - Plan, Elevation, Section Views and Details You will need to understand how to read a set of...
Read more
HVAC Mechanical Drawings
Chapter #4 - HVAC Mechanical Drawings The mechanical drawings we will be dealing with are specifically related to the HVAC...
Read more
Latest Videos
How to size Plumbing Water pipes using Fixture Units
12:26
Refrigerant Piping Design Basics
04:48
VRF Heat Pump vs Heat Recovery
08:16
How a Fan Wall or Fan Array Works
07:42
6 Steps for Designing HVAC DDC Controls
13:38
Heat Recovery Ventilators and How They Work
12:59
How Do Air Conditioners Work
14:08
How do Chilled Beams Work - Active and Passive
13:43
Best Plumbing Estimating Spreadsheet
15:33
Best Mechanical Estimating Software Cost and Features
24:13
Basic HVAC Controls
17:48
Data Center HVAC Systems
20:14
How a Condensing Boiler Works
09:11
How Fan Coils Work in HVAC Systems
07:24
Sensible and Latent Heat Transfer Formula for Air
04:26
Sensible Heat Transfer Equation for Air
03:40
Sensible Heat Transfer Equation for Water
03:18
Rooftop Packaged HVAC Units Explained
09:52
How to Figure Construction Labor Rates with Burden
05:26
What is a BTU or Ton of Air Conditioning
10:20
How Variable Frequency Drives Work in HVAC Systems
13:38
How a Variable Air Volume VAV System Works
16:54
How to Read Pump Chart and Select Pump
16:15
How Air and Water Cooled Chillers Work
13:14
How Cooling Towers Work Counterflow vs Crossflow
08:23
Top 12 Construction Bidding Websites
13:23
Top 3 Things to Know Before Bidding Commercial Construction
15:40
How to Read Construction Specifications
12:38
Fan Laws How to Calculate CFM BHP SP RPM
13:35